F835 (Center Pitch: 3.50mm/138mil)

F835 (Center Pitch: 3.50mm/138mil)

  • Maximum stroke: 5.0mm
  • Recommended stroke: 4.0mm
  • Spring pressure at recommended stroke: 110gf
  • Initial spring pressure: 50gf

Probe (mm)

F835 (Center Pitch: 3.50mm/138mil)

Recommended drill size H885

Material Drill φ (mm)

(With Nar)

Drill φ (mm)

(No narration)

EP 105 (CEM1, Trolitax) 3.00-3.02 2.98-2.99
HGW 2372.1 (FR4)

Tip shape

05 BeCu ; G
* Please refer to Table 1 below for details

09 BeCu ; G
* Please refer to Table 1 below for details

11 BeCu ; G
* Please refer to Table 1 below for details

12 BeCu ; G
* Please refer to Table 1 below for details

table 1
series Tip shape No. Center pin (ФA) mm Shielding plunger (ФB) mm Overlap

(C) mm

Height (H) mm from the board surface Overall length (L) mm Version Version.
F835 05 05 0005 0.52 2.65 -1.60 10.20 45.00 ――――
F835 05 05 0006 0.52 3.20 -1.90 10.50 45.30 ――――
F835 09 09 0001 0.64 2.17 0.00 0.00 10.00 44.80 ――――
F835 11 11 0003 0.45 2.66 -0.90 9.00 43.80 ――――
F835 12 0004 0.60 3.20 -0.20 9.00 43.80 ――――
F835 16 16 0001 0.64 2.17 0.00 0.00 10.00 44.80 ――――

Standard specifications

F835
  Center pin Maximum stroke 5.0mm
Recommended stroke 4.0mm
Spring pressure at the recommended stroke 110gf
Initial spring pressure 50gf
Shielding plunger Maximum stroke 5.0mm
Recommended stroke 4.0mm
Spring pressure at the recommended stroke 300gf
Initial spring pressure 80gf

Material

Center pin Shielding plunger
Plunger BeCu ・ Au plating
sleeve Brass / Au plating
spring SWP / Ag plating (SUS / Ag plating) SWP / Ag plating
socket Brass / Au plating

Electrical characteristics

Center pin Shielding plunger
Rated current 2.0A 10.0A

Applicable temperature

Center pin Shielding plunger
Standard specifications  -20 to + 80 ℃

How to order

For order code [F835 16B 0001 G410]

F835 16B  0001 G 410
Series: F835 Tip shape: 16

Material: B = BeCu

0001: “No.” in Table 1 Surface treatment: G = Au plating Spring pressure: 410 = 410g
* 1. When ordering a socket, please refer to the name displayed above the socket drawing. Example: H885KB, H885RD, H880AE
* 2, F835 can move the outer contact and the inner contact separately.

 

* Specifications are subject to change without notice.