HF-101
Mechanical Specification
Signal Conductor | Shielding Plunger | |
Maximum stroke | 2.6mm | 1.5mm |
Recommended Stroke | 1.8mm | 1.5mm |
Spring pressure during recommended stroke | 60gf | 120gf |
Coaxial cable length | 35cm/60cm |
Materials and Plating
Plunger | BeCu, Gold plated | |
Outer conductor | Brass, Gold plated | |
insulator | Teflon |
Electrical Specification
Signal Conductor | Shielding Plunger | |
Adapted current (maximum) | 3.0A | 5.0A |
Test Frequency | 2.4GHz@ -1dB , 7.0GHz@ -3dB | |
impedance | 50Ω |
HOW TO ORDER
When ordering a coaxial high-frequency probe, please specify the [tip shape] as shown below.
HF-101-[ Tip Shape ]-[ Signal Outer Diameter ]-[ Coaxial Cable Length ]
Example: HF-101-CA-E2-35
When ordering a replacement probe, please specify the [tip shape] as shown below.
HF-101-[ Tip Shape ]-[ Signal Outer Diameter ]
Example: HF-101-CA-E2
* Specifications are subject to change without notice.