HF-101
Mechanical Specification
| Signal Conductor | Shielding Plunger | |
| Maximum stroke | 2.6mm | 1.5mm |
| Recommended Stroke | 1.8mm | 1.5mm |
| Spring pressure during recommended stroke | 60gf | 120gf |
| Coaxial cable length | 35cm/60cm |
Materials and Plating
| Plunger | BeCu, Gold plated | |
| Outer conductor | Brass, Gold plated | |
| insulator | Teflon | |
Electrical Specification
| Signal Conductor | Shielding Plunger | |
| Adapted current (maximum) | 3.0A | 5.0A |
| Test Frequency | 2.4GHz@ -1dB , 7.0GHz@ -3dB | |
| impedance | 50Ω | |
HOW TO ORDER
When ordering a coaxial high-frequency probe, please specify the [tip shape] as shown below.
HF-101-[ Tip Shape ]-[ Signal Outer Diameter ]-[ Coaxial Cable Length ]
Example: HF-101-CA-E2-35
When ordering a replacement probe, please specify the [tip shape] as shown below.
HF-101-[ Tip Shape ]-[ Signal Outer Diameter ]
Example: HF-101-CA-E2
* Specifications are subject to change without notice.